(6)
5. Incorrect electrical source – confirm that the
main electrical supply is the same as that
specified on the data label.
6. The ambient temperature is too high.
7. Too much food is loaded at one time.
8. More than one source of energy is used at the
same time.
If the freezer still does not work properly, call a
service technician.
The sealed cooling system must not be opened,
since it contains corroding chemicals under
high pressure.
MAINTENANCE
Always turn to a qualified Electrolux Service agent
who is familiar with LP gas systems and freezers.
We recommend that a service technician check the
freezer once a year.
1 Check all connections in the LP gas
system for gas leaks. Connections can be
tested for leaks using a soap solution. Do
not use a naked flame!
1 Check that the burner is clean and free
from combustible material.
SOME USEFUL HINTS
Make sure that:
1 Defrosting is carried out periodically.
1 The freezer is clean and dry with the lid
left open when it is not to be used for
some time.
1 Liquids or items with a strong odour are
well packed
1 There is free air circulation over the
cooling unit at the rear of the freezer.
SERVICE
Service and spare parts are obtained from your
dealer or Electrolux – consult the telephone
directory.
TECHNICAL DATA
Overall dimensions, freezer
Height 850 mm
Width 920 mm
Depth (incl. cooling unit) 750 mm
Capacity
Gross 185 litres
Weight (without packing) 50 kg
Electrical data
Input all Voltages 300 Watt
LP Gas data
Input, max. 32 g/hour
Rating 440 Watt
Pressure 28 – 30 mbar
Category I
3 (BP 30)
Propane/Butabe (50/50)
&
I
3+ (28-30/37)
Jet size “4”
Cooling medium Ammonia
INSTALLATION INSTRUCTIONS
This appliance shall be installed in
accordance with the regulations in force
PLACEMENT OF THE FREEZER
The room should have a capacity (length x width
x height) of at least 20m
3
and must be adequately
ventilated and be in accordance with all relevant
national and local regulations.
The freezer must be used in a well-ventilated
area, above ground and protected from rain.
The freezer may never be used in a
basement
It is important that the freezer is not subjected to
radiated heat from a stove, the sun etc. Do not
place in front of a window.
For best results at high ambient temperatures
there must be a free air circulation over the
cooling unit at the rear of the freezer but not a
draught. The freezer is designed for a
freestanding installation and the clearance to the
rear wall should be at least 100mm and to
possible sidewalls should be at least 80mm. The
cooling fins at the rear of the cabinet must not be
covered. (Fig. 2)
The freezer should be placed close enough to a
electrical supply so that the plug is assessable to
be disconnected.
Commenti su questo manuale