5
GREEN-AND-YELLOW: EARTH
BLUE: NEUTRAL
BROWN: LIVE
As the colours of the wires in the mains lead may not correspond
with the coloured markings identifiying the terminals in your plug,
proceed as follows: the wire which is coloured GREEN-
AND-YELLOW must be connected to the terminal in the plug
which is marked with the letter E or by the earth symbol or
coloured green or green-and-yellow. The wire which is coloured
BLUE must be connected to the terminal which is marked with the
letter N or coloured black. The wire which is coloured BROWN
must be connected to the terminal which is marked with the letter
L or coloured red.
WARNING - THIS APPLIANCE MUST BE EARTHED!
If a 13 amps (B.S. 1363) fused-plug is used, it should be fitted with a 3 amp fuse. In other cases, the
circuit to which the refrigerator is connected should be fitted with a 5 amp fuse.
To turn on (Fig. 1)
Turn thermostat knob (A) clockwise to position 7/MAX. Only after approximately 1 hour will the unit
become noticably cool (frost on evaporator).
The temperature can be regulated using the thermostat knob: '0'=off, 1-7 increasing degrees of
coolness.
After sufficient cooling (approximately 5 hours), the thermostat position can be set to a lower
temperature, between 2-5. The thermostat will now automatically regulate the set temperature.
To turn off (Fig. 1)
Turn thermostat knob (A) anticlockwise to position '0' (a slight resistance will be felt just before this
position).
Pull out mains plug.
7. D/C operation
Do not use any additional form of energy (mains/gas). A safety fuse must be installed in the electricity
supply between battery and refrigerator in a duct.
12 V: maximum 15 amps; 24 V: maximum 7.5 amps.
It is not necessary to consider the polarity when connecting the unit. Check that the battery voltage
corresponds with the line-voltage data on the cooling unit type-plate. If no battery is used
independently of the vehicle, the cooling unit is only to be used when the vehicle is in motion, since,
when the engine is not running, the battery can discharge to such an extent that the engine will not
restart.
Recommendation: Before a journey, pre-cool the unit using the supply voltage.
To turn on
The car plug fitted to the connecting cable is to be plugged into the socket/cigar lighter (car plugs are
not supplied with every model).
max. cable lengths
Cable cross section 12 V 24 V
2.5 mm
2
until 2.5 m 5 m
4.0 mm
2
until 4.0 m 8 m
6.0 mm
2
until 6.0 m 12 m