6. FAULT TRACING
6.1 SCHEME FOR FAULT TRACING
Use caution when fault tracing on Travel Power. Please observe that
this is a 230 V installation.
Is there
voltage in the
230 V-outlet?
NO
Is the red LED
lit?
Yes Go to
paragraph
6.2
NO
Is the green
LED lit?
Yes Are the 16 A
fuses OK?
YES Is the RCCB
OK?
YES Is the
switching
device OK?
YES Are the 230 V
wiring and
connectors
OK?
YES Go to
paragraph
6.3
NO NO NO NO
NO
Find out the
cause
Check
connected
equipment
Replace or
repair
Fix 230 V
wiring or
connectors
Is the on-off
switch in the
on-position?
YES Is the fan
moving
inside the
power box?
YES Is the
generator rpm
sufficient?
YES Go to
paragraph
6.3
NO
NO NO Increase the
rpm
Turn on the
on-off switch
Is the belt
transmission
OK?
YES Are the cables
OK? Is it
voltage in
both ends?
YES Go to
paragraph
6.3
NO
NO
Take care of
broken cables
or connectors
Take care of
belt
transmission